HOME | Products | Recycling Preparative HPLC | Other selective columns

Other selective columns

Please select one of the following tabs of columns.


Other selective columns

Please select one of the following tabs of columns.


iCHIRAL Series

▮Immobilized Polysaccharide chiral columns (Made by Daicel)

This highly solvent-resistant column series was developed with a concept of "Chiral columns that can be used with broad range of organic solvents as eluents". You can use alkanes and alcohols in addition to all the solvents being used for HPLC such as Ethyl Acetate, THF and halogenated solvents. Further, Semi-prep columns (20mm ID) are "footless columns", meaning giving very sharp peaks with no tailing, which results in larger injection loadability and higher enantiomeric resolution.
 

Product Type ID
(mm)
Length
(mm)
Particle Size
(μm)
Flow Rate
(mL/min)
Product Code
CHIRALPAK®
IA IB IB N-5 IC ID IE IF IG IH IJ
 Guard cartridge for analytical column 4 10 5   80311 81311 88311 83311 84311 85311 86311 87311 89311 90311
 Analytical column 4.6 50 5 0.5 - 3.0 80322 81322 88322 83322 84322 85322 86322 87322 89322 90322
4.6 100 5 0.5 - 3.0 80323 81323 88323 83323 84323 85323 86323 87323 89323 90323
4.6 150 5 0.5 - 3.0 80324 81324 88324 83324 84324 85324 86324 87324 89324 90324
4.6 250 5 0.5 - 3.0 80325 81325 88325 83325 84325 85325 86325 87325 89325 90325
 Guard cartridge for semi-prep column 10 20 5   80337 81337 88337 83337 84337 85337 86337 87337 89337 90337
 Semi-prep column 10 250 5 2.4 - 14 80335 81335 88335 83335 84335 85335 86335 87335 89335 90335
20 250 5 9.5 - 57 80345 81345 88345 83345 84345 85345 86345 87345 89345 90345
 Guard cartridge for preparative 50 100 20   80253   88253 83253 84253 85253 86253 87253 89253 90253
 Preparative column 30 250 5 21 - 128 80375 81375 88375 83375 84375 85375 86375 87375 89375 90375
50 500 20 59 - 354 80256   88256 83256 84256 85256 86256 87256 89256 90256

※1: The flow rates are for reference only, Actual flow rate must be controlled so that the pressure does not exceed the limit specified in the Operation Manual.
※2: Three pieces per set. To use the cartridge, Cartridge Holder (Item #00011) is needed.
※3: Analytical columns must be used with analytical HPLC. 

iCHIRAL Series
▮Immobilized Polysaccharide chiral columns (Made by Daicel)
This highly solvent-resistant column series was developed with a concept of "Chiral columns that can be used with broad range of organic solvents as eluents". You can use alkanes and alcohols in addition to all the solvents being used for HPLC such as Ethyl Acetate, THF and halogenated solvents. Further, Semi-prep columns (20mm ID) are "footless columns", meaning giving very sharp peaks with no tailing, which results in larger injection loadability and higher enantiomeric resolution.
 

Product Type ID
(mm)
Length
(mm)
Particle
(μm)
Flow Rate
(mL/min)
Product Code
CHIRALPAK®
IA IB IB N-5 IC ID IE IF IG IH IJ
 Guard 4 10 5   80311 81311 88311 83311 84311 85311 86311 87311 89311 90311
 Analytical 4.6 50 5 0.5 - 3.0 80322 81322 88322 83322 84322 85322 86322 87322 89322 90322
4.6 100 5 0.5 - 3.0 80323 81323 88323 83323 84323 85323 86323 87323 89323 90323
4.6 150 5 0.5 - 3.0 80324 81324 88324 83324 84324 85324 86324 87324 89324 90324
4.6 250 5 0.5 - 3.0 80325 81325 88325 83325 84325 85325 86325 87325 89325 90325
 Guard 10 20 5   80337 81337 88337 83337 84337 85337 86337 87337 89337 90337
 Semi-prep 10 250 5 2.4 - 14 80335 81335 88335 83335 84335 85335 86335 87335 89335 90335
20 250 5 9.5 - 57 80345 81345 88345 83345 84345 85345 86345 87345 89345 90345
 Guard 50 100 20   80253   88253 83253 84253 85253 86253 87253 89253 90253
 Preparative 30 250 5 21 - 128 80375 81375 88375 83375 84375 85375 86375 87375 89375 90375
50 500 20 59 - 354 80256   88256 83256 84256 85256 86256 87256 89256 90256

※1: The flow rates are for reference only, Actual flow rate must be controlled so that the pressure does not exceed the limit specified in the Operation Manual.
※2: Three pieces per set. To use the cartridge, Cartridge Holder (Item #00011) is needed.
※3: Analytical columns must be used with analytical HPLC. 

Optical isomer separation columns (Packed particle size 5μm)

▮ JAIGEL-OA Series

Item model Type Chiral component Mode Applications Invered type
JAIGEL-OA2000 Amide (R)-phenylglycine NP Ester, Aromatic, Carbonyl, Carboxylic, Hydroxyl, Alcohol -OA2000S
JAIGEL-OA2500 (R)-1-naphthylglycine RP -OA2500S
JAIGEL-OA2000-I Amide  (R)-phenylglycine NP -OA2000S-I
JAIGEL-OA2500-I (R)-1-naphthylglycine  RP -OA2500S-I
JAIGEL-OA3100 Urea  (S)-valine RP Carboxylic acid, Amino acid (esp. Acylated-, Urethane-, Dansyl- Amino acid), Alcohol group  -OA3100R
JAIGEL-OA3200 (S)-tert-leucine RP -OA3200R
JAIGEL-OA3300 (R)-phenylglycine RP -OA3300S
JAIGEL-OA4000 (S)-valine, (S)-1-(a-naphthyl)ethylamine NP  Amines, Amino Alcoholic drug and alcohol group, ester -OA4000R
JAIGEL-OA4100 (S)-valine, (R)-1-(a-naphthyl)ethylamine NP -OA4100R
JAIGEL-OA4400 (S)-proline, (S)-1-(a-naphthyl)ethylamine NP Amines, Amino Alcoholic drug and alcohol group, ester -OA4400R
JAIGEL-OA4500 (S)-proline, (R)-1-(a-naphthyl)ethylamine NP -OA4500R
JAIGEL-OA4600 (S)-tert-leucine, (S)-1-(a-naphthyl)ethylamine NP Amines, Amino Alcoholic drug and alcohol group, ester -OA4600R
JAIGEL-OA4700 (S)-tert-leucin, (R)-1-(a-naphthyl)ethylamine NP -OA4700R
JAIGEL-OA4800 (S)-indoline-2-carboxylic acid, (S)-1-(a-naphthyl)ethylamine NP Amines, Amino Alcoholic drug and Amino acid
JAIGEL-OA4900 (S)-indoline-2-carboxylic acid, (R)-1-(a-naphthyl)ethylamine NP - 
JAIGEL-OA5000 Ligand Exchange (D)-penicillamine RP Amino acid, Oxyacid optical isomer -OA5000L
JAIGEL-OA5500 (R)-2-amino-1, 1-bis(2-butoxy-5-tert-butylphenyl)-phenylpropanol-1 RP

Aromatic primary amine, Amino alcohol, Amino acid optical isomer

JAIGEL-OA6000 (L)-tartaric acid, (R)-1-(a-naphthyl)ethylamine RP β-Amino acid, β-Oxyacid, Amino alcohol group -OA6000R 
JAIGEL-OA6100 (L)tartaric acid, (S)-valine, (S)-1-(a-naphthyl)ethylamide RP -OA6100R 
JAIGEL-OA7000 Chemical Bond β-cyclodextrin, sugar chain RP Aromatic, Aliphatic ketone, Amino alcohol group
JAIGEL-OA7100 β-cyclodextrin, alkyl chain RP
JAIGEL-OA7500 Methylated-β-cyclodextrin,alkyl chain RP Aromatic, Aromatic alcohol
JAIGEL-OA8000 Chiral crown ether RP/NP Chiral amine, Amino acid, Amino alcohol group

OA series colum models

Model Preparativec column
ID × Length (mm)
Analytical column
ID × Length (mm) 
Pre-column
ID × Length (mm)
OA2000 - OA4000 -20
(20.0×250)
-10
(10.0×250)
-8
(8.0×250)
-4
(4.6×250)
-P
(4.0×10)
OA5000 - OA6100 -20
(20.0×150)
-10
(10.0×150)
-8
(8.0×150)
-4
(4.6×150)
-P
(4.0×10)
OA7000 - OA8000 -4
(4.6×250)

Fullerene separation column(NACALAI TESQUE,INC.)

▮ BUCKYPREP Series

Buckyprep series is specially designed for fullerene separation.
This is a most suitable column with its high performance as it takes 10 times larger quantity of sample at a time and complete separation within half of the time GPC columns generally take.
For fullerene separation, Buckyprep column with our recycling preparative HPLC is the world benchmark of HPLC column.

 
BUCKYPREP series colum models

Item model ID × Lenght Pre-column ID × Lenght Applications
COSMOSIL Buckyprep 20 × 250mm Buckyprep guard column 20 × 50mm Fullerene, Derivatized fullerene
28 × 250mm 28 × 50mm
50 × 250mm 50 × 50mm
COSMOSIL Buckyprep-M 20 × 250mm Buckyprep-M guard column 20 × 50mm Endohedral metall of fullerene
28 × 250mm 28 × 50mm 
50 × 250mm 50 × 50mm

Optical isomer separation columns
(Packed particle size 5μm)
▮ JAIGEL-OA Series

JAIGEL Type Chiral
component
Mode Applications Invered type
OA2000 Amide (R)-phenylglycine NP Ester, Aromatic, Carbonyl, Carboxylic, Hydroxyl, Alcohol -OA2000S
OA2500 (R)-1-naphthylglycine RP -OA2500S
OA2000-I (R)-phenylglycine NP -OA2000S-I
OA2500-I (R)-1-naphthylglycine RP -OA2500S-I
OA3100 Urea (S)-valine RP Carboxylic acid, Amino acid (esp. Acylated-, Urethane-, Dansyl- Amino acid), Alcohol group -OA3100R
OA3200 (S)-tert-leucine RP -OA3200R
OA3300 (R)-phenylglycine RP -OA3300S
OA4000 (S)-valine, (S)-1-(a-naphthyl)ethylamine NP  Amines, Amino Alcoholic drug and alcohol group, ester -OA4000R
OA4100 S)-valine, (R)-1-(a-naphthyl)ethylamine NP -OA4100R
OA4400 (S)-proline, (S)-1-(a-naphthyl)ethylamine NP Amines, Amino Alcoholic drug and alcohol group, ester -OA4400R
OA4500 (S)-proline, (S)-1-(a-naphthyl)ethylamine NP -OA4500R
OA4600 (S)-tert-leucine, (S)-1-(a-naphthyl)ethylamine NP Amines, Amino Alcoholic drug and alcohol group, ester -OA4600R
OA4700 (S)-tert-leucine, (S)-1-(a-naphthyl)ethylamine NP -OA4700R
OA4800 (S)-indoline-2-carboxylic acid, (S)-1-(a-naphthyl)ethylamine NP Amines, Amino Alcoholic drug and Amino acid
OA4900 (S)-indoline-2-carboxylic acid, (S)-1-(a-naphthyl)ethylamine NP - 
OA5000 Ligand Exchange (D)-penicillamine RP Amino acid, Oxyacid optical isomer -OA5000L
OA5500 (R)-2-amino-1, 1-bis(2-butoxy-5-tert-butylphenyl)-phenylpropanol-1 RP

Aromatic primary amine, Amino alcohol, Amino acid optical isomer

OA6000 (L)-tartaric acid, (R)-1-(a-naphthyl)ethylamine RP β-Amino acid, β-Oxyacid, Amino alcohol group -OA6000R 
OA6100 (L)tartaric acid, (S)-valine, (S)-1-(a-naphthyl)ethylamide RP -OA6100R 
OA7000 Chemical Bond β-cyclodextrin, sugar chain RP Aromatic, Aliphatic ketone, Amino alcohol group
OA7100 β-cyclodextrin, alkyl chain RP
OA7500 Methylated-β-cyclodextrin,alkyl chain RP Aromatic, Aromatic alcohol
OA8000 Chiral crown ether NP /RP Chiral amine, Amino acid, Amino alcohol group

 
Model Preparative
IDxLength (mm)
Analytical
IDxLength (mm)
Pre-
column
OA2000 - OA4000 -20
(20x250)
-10
(10x250)
-8
(8x250)
-4
(4.6x250)
-P
(4x10)
OA5000 - OA6100 -20
(20x150)
-10
(10x150)
-8
(8x150)
-4
(4.6x150)
-P
(4x10)
OA7000 - OA8000 -4
(4.6×250)

Fullerene separation column
from NACALAI TESQUE, INC.
▮ BUCKYPREP Series for Fullerene
Buckyprep series is specially designed for fullerene separation.
This is a most suitable column with its high performance as it takes 10 times larger quantity of sample at a time and complete separation within half of the time GPC columns generally take.
For fullerene separation, Buckyprep column with our recycling preparative HPLC is the world benchmark of HPLC column.
 
BUCKYPREP series columns

COSMOSIL IDxLenght
(mm)
Pre-column Applications
Buckyprep Packed 20x250 Buckyprep
Guard Column
Fullerene
Derivatized fullerene
28×250
50×250
Buckyprep-M Packed 20×250 Buckyprep-M
Guard Column
Endohedral metall fullerene
28×250