HOME | Products | Recycling Preparative HPLC | Organic GPC Columns

Organic GPC Columns

Please select one of the following tabs of columns.

Organic GPC Columns

Please select one of the following tabs of columns.


High speed and solvent interchangeable organic GPC Columns

▮ JAIGEL-HR Series

JAIGEL-H series columns have an established reputation and now have a new generation called JAIGEL-HR and JAIGEL-HR Plus.
 
The original JAIGEL-H series has flow rate of 3.5 mL/min and the new JAIGEL-HR series has 4 times faster flow rate of 15 mL/min maximum.

 
It also has higher throughput and higher resolution that increase amount of sample per injection.

 
In addtion, it has capability of solvent interchangeability.

 
Possible solvent in JAIGEL-HR : THF, DMF, Ethylacetate, Dichloroethane, Chloroform, Toluene, etc
 
Possible solvent in JAIGEL-HR Plus : In addition to THF, DMF, Ethylacetate, Dichloroethane, Chloroform and Toluene,  JAIGEL-HR Plus are compatible to CHCl3/MeOH 50/50, CHCl3/HFIP 90/10, DMF/MeOH 80/20, Acetone, Hexane, NMP, DMAc, DMSO, Dichloromethane, o-DCB, MEK and Pyridine.
 
* DMF can be used in JAIGEL-2HR 2.5HR 3HR 4HR and 5HR. However, DMF is not compatible with 1HR.
 
HR series column models  
Exclusion limit
(PS equivalent)
Preparative column Pre-column
HR Plus HR series ID 8 mm ID 20 mm
ID 20 x 600 mm ID 20 x 600 mm ID 40 x 600 mm Length 40 mm Length 50 mm
1,000   1HR
(>24,000) 
-  JAIGEL-HR-P
for ID 20 
 JAIGEL-HR-40P
for ID 40    
5,000 2HR Plus
(>30,000)
- 2HR-40
(>24,000)
20,000 2.5HR Plus
(>30,000)
- 2.5HR-40
(>24,000)
70,000   3HR
(>24,000)
-
500,000   4HR
(>24,000)
-
5,000,000   5HR
(>20,000)
-

Standard packed solvent : Chloroform
 
Pre-column
Precolumn is a guard column to protect performance and efficiency of preparative column.
It is placed before main columns and has similar fillers as JAIGEL-HR series.
 
Flow rate
ID Flow rate
Regular use Maximum
20 mm 10 mL/min HR         : 15 mL/min
HR Plus : 20 mL/min
40 mm  40 mL/min

High speed Organic GPC Columns (Chloroform or THF)

▮ JAIGEL-HH  Series

The original organic GPC JAIGEL-H series columns can now flow at 7.5 mL/min and become JAIGEL-HH series, that is twice faster than H series.
JAIGEL-HH series have the exact same packing material that have been well received for many years.
Twice as fast flow rate makes the retention time only half the time it used to take.
 
Standard packed solvent : Chloroform or THF
The JAIGEL-HH series can not change solvents from the packed solvent at factory. 
 
Theoretical plate guarantee for 6 months. After 6 months from installation, if the theoretical plate drops lower than 13,000, repacking or replacement will be offered.
 
HH series column models

Item model Exclusion limit
(PS equivalent)
Preparative column Pre-column
ID 20 mm ID 8 mm ID 20 mm
 Length 600 mm Length 40 mm Length 50 mm
JAIGEL-1HH 1,000 1HH (>13,000)  JAIGEL-HH-P
for ID 20
JAIGEL-HH-40P
for ID 40
JAIGEL-2HH 5,000 2HH (>13,000) 
JAIGEL-2.5HH 20,000 2.5HH (>13,000) 
JAIGEL-3HH 70,000 3HH (>13,000) 
JAIGEL-4HH 500,000 4HH (>13,000)
JAIGEL-5HH 5,000,000 5HH Please ask

Pre-column
Precolumn is a guard column to protect performance and efficiency of preparative column.
It is placed before main columns and has similar fillers as JAIGEL-HH series.
  
Flow rate

ID Maximum flow rate (mL/min)
20 mm 7.5

Original GPC Columns

▮ JAIGEL-H Series

This is a classic highly cross-linked polystyrene/divinylbenzene (PS/DVB) packed column.
Maximum sample amount of injection at a time is up to 300mg with 2 set of JAIGEL-H columns connected in series.
JAIGEL-H-40 has wider inner diameter (40mm) and 4 times more sample amount can be injected at a time. 
JAIGEL-H series are very robust and can last for many years.
 
Standard set up : Connecting two columns in series (Best suits for recycling)
Standard packed solvent : Chloroform or THF
Theoritical plate gurantee for 6 months. After 6 months from installation, if the theoritical plate drops lower than 13,000, repacking or replacement will be offered.
Other possible filling solvent : Experienced in packing in toluene, DMF, Dichloroethane. Please feel free to ask for more details.
 
H series column models

Item model Exclusion limit
(PS equivalent) 
Preparative column Analytical column Larger scale
ID 20 mm ID 40 mm ID 8 mm ID 100 mm
Length 600 mm Length 600 mm Length 500 mm Length 600 mm
JAIGEL-1H 1,000 1H
(>13,000) 
1H-40
(>10,000) 
1H-A
(>16,000) 
----------
JAIGEL-2H 5,000 2H
(>13,000) 
 2H-40
(>10,000) 
2H-A
(>16,000) 
 2H-100
(>10,000) 
JAIGEL-2.5H 20,000 2.5H
(>13,000) 
2.5H-40
(>10,000) 
2.5H-A
(>16,000)   
2.5H-100
(>10,000)  
JAIGEL-3H 70,000  3H
(>13,000) 
 3H-40
(>10,000) 
 3H-A
(>16,000) 
----------
JAIGEL-4H 500,000 4H
(>13,000) 
4H-40
(>6,500)  
4H-A
(>15,000)  
----------
JAIGEL-5H 5,000,000 5H
Please ask
5H-40
Please ask
5H-A
(>15,000) 
 ----------
JAIGEL-6H 50,000,000 6H
Please ask
6H-40
Please ask
6H-A
Please ask
 ----------
JAIGEL-MH 20,000,000 MH
Please ask
---------- MH-A
Please ask
 ----------

Pre-column
Precolumn is a guard column to protect performance and efficiency of preparative column.
It is placed before main columns and has similar fillers as JAIGEL-H series. 

Type

ID x Length

Designed for use with

JAIGEL-H-P

8 x 40 mm

Each series of H, HH, H-A

JAIGEL-HH-40P

20 x 50 mm

H-40 series

JAIGEL-H-100P

40 x 50 mm

H-100 series  

 Flow rate

ID Flow rate (mL/min)
Regular use Maximum
20 mm 3.5 4.0
40 mm 9.0 - 14.0 16.0
8 mm 1.0 1.6

High speed and solvent changeable
Organic GPC Columns
▮ JAIGEL-HR Series 
 
Standard packed solvent : Chloroform
Compatible solvents : DMF, Ethylacetate, Dichloroethane, Chloroform, Toluene, etc * DMF can be used in JAIGEL-2HR 2.5HR 3HR 4HR and 5HR. However, DMF is not compatible with 1HR.
 

The original JAIGEL-H series has flow rate of 3.5 mL/min and the new JAIGEL-HR series has 4 times faster flow rate of 15 mL/min maximum.
 

It also has higher throughput and higher resolution that increase amount of sample per injection.

 

In addtion, it has capability of multiple solvents interchangeability.

 
HR series  column models

 

JAIGEL Exclusion
limit

(PS)
Preparative column Pre-column
20 mm ID 40 mm ID 8 mm ID 20 mm ID
600 mm 600 mm 40 mm 50 mm
1HR 1K 1HR
(>24,000) 
- -HR-P -HR-40P
2HR 5K 2HR
(>30,000)
2HR-40
(>24,000)
2.5HR 20K 2.5HR
(>30,000)
2.5HR-40
(>24,000)
3HR 70K 3HR
(>24,000)
-
4HR 500K 4HR
(>24,000)
-
5HR 5000K 5HR
(>20,000)
-

 
Pre-column ID × Length Designed for use with
JAIGEL-HR-P 8 x 40 mm 20 mm ID HR
JAIGEL-HR-40P 20 x 50 mm 40 mm ID HR

 
ID Flow rate (mL/min)
Regular use Maximum
 20 mm 10 HR : 15
HR Plus : 20
 40 mm  40 

 


High speed Organic GPC Columns
(Chloroform or THF)
▮ JAIGEL-HH  Series
The original organic GPC JAIGEL-H series columns can now flow at 7.5 mL/min and become JAIGEL-HH series, that is twice faster than H series.
JAIGEL-HH series have the exact same packing material that have been well received for many years.
Twice as fast flow rate makes the retention time only half the time it used to take.
 
Standard packed solvent : Chloroform or THF
The JAIGEL-HH series can not change solvents from the packed solvent at factory. 
 
Theoretical plate guarantee for 6 months. After 6 months from installation, if the theoretical plate drops lower than 13,000, repacking or replacement will be offered.
 
HH series column models

JAIGEL Exclusion
limit

(PS)
Preparative Pre-column
20 mm ID 8 mm ID 20 mm ID
600 mm 40 mm 50 mm
1HH 1K 1HH
(>13,000) 
HH-P HH-40P
2HH 5K 2HH
(>13,000) 
2.5HH 20K 2.5HH
(>13,000) 
3HH 70K 3HH
(>13,000) 
4HH 500K 4HH
(>13,000)
5HH 5000K 5HH
(Please ask)

 
Pre-column ID × Length Designed for use with
JAIGEL-H-P 8 x 40 mm 20 mm ID of H, HH, H-A
JAIGEL-HH-40P 20 x 50 mm 40 mm ID of H, HH

 
ID Max flow rate (mL/min)
20 mm 7.5

 


Original GPC Columns
▮ JAIGEL-H Series
This is a classic highly cross-linked polystyrene/divinylbenzene (PS/DVB) packed column. Maximum sample amount of injection at a time is up to 300 mg with 2 set of JAIGEL-H columns connected in series.
JAIGEL-H-40 has wider 40 mm ID and 4 times more sample amount can be injected at a time. JAIGEL-H series are very robust and can last for many years.
 
Standard set up : Connecting two columns in series (Best suits for recycling)
 
Standard packed solvent : Chloroform or THFTheoritical plate gurantee for 6 months. After 6 months from installation, if the theoritical plate drops lower than 13,000, repacking or replacement will be offered.
 
Other possible filling solvent : Experienced in packing in toluene, DMF, Dichloroethane. Please feel free to ask for more details.
 
H series column models 


JAIGEL
Exclusion
limit

(PS)
Preparative column Analytical Large scale
20 mm ID 40 mm ID 8 mm ID 100 mm ID
600 mm 600 mm 500 mm 600 mm
1H 1K 1H
(>13,000) 
1H-40
(>10,000) 
1H-A
(>16,000) 
----------
2H 5K 2H
(>13,000) 
 2H-40
(>10,000) 
2H-A
(>16,000) 
 2H-100
(>10,000) 
2.5H 20K 2.5H
(>13,000) 
2.5H-40
(>10,000) 
2.5H-A
(>16,000)   
2.5H-100
(>10,000)  
3H 70K  3H
(>13,000) 
 3H-40
(>10,000) 
 3H-A
(>16,000) 
----------
4H 500K 4H
(>13,000) 
4H-40
(>6,500)
4H-A
(>15,000)  
----------
5H 5000K 5H
Please ask
5H-40
Please ask
5H-A
(>15,000) 
 ----------
6H 50000K 6H
Please ask
6H-40
Please ask
6H-A
Please ask
 ----------
MH 20000K MH
Please ask
---------- MH-A
Please ask
 ----------

 
Pre-column ID × Length Designed for use with
JAIGEL-H-P 8 x 40 mm 20 mm ID of H, H-A
JAIGEL-H-40P 20 x 50 mm 40 mm ID of H
JAIGEL-H-100P 40 x 50 mm 100 mm ID of H

 
ID Flow rate (mL/min)
Regular use Maximum
20 mm 3.5 4.0
40 mm 9.0 - 14.0 16.0
8 mm 1.0 1.6