HOME | Products | Recycling Preparative HPLC | Copy LaboACE LC-7080

LaboACE LC-7080

LaboACE LC-7080

Auto Model

Auto Model

Automate Your Operation
LaboACE LC-7080 offers operators simple and intuitive event programming. Events such as repeating sample injection, discarding junk peaks, recycling and sample collecting can be setup easily. A new feature, Peak Detection, automatically collects samples when peaks start to show.
 
 - Repeat sample injection
 - Stacked injection for solvent and time saving
 - Improving peak resolution by recycling separation
 - Discarding unwanted peaks
 - Fraction collection triggered by peaks
 
Multiple ways of injection
Manual injectior and Repeat injector are standard. Repeat injector is a direct auto sample loading system for large volume injection or additional same sample injection repeatedly. Optional loop injector for higher reproducibility is also available.
 
Peak Detection
Automatically collects samples when peaks start to show, triggered by time, peak slope and/or peak height. You will not miss collecting your target peaks.
 
Recycling preparative chromatograph (patented)
The system is equipped with non-diffusion recycling system (patented) that prevents the sample from running back into solvent line, baseline shifting, broadening and damaging detectors with back pressure. It protects detectors, columns and your precious samples.
 
Auto Cleanup Function
It cleans inside the flow channels automatically. Auto cleanup function along with the patented non-diffusion recycling system prevent system residual contamination so that you can obtain ultra pure compounds with confidence. Solvent replacement can also be made much easily.
 
Reliable Solvent Delivery
With more than 50 years' experience of developing recycling technology, the system has JAI-made serial double plunger pump optimized for stable delivery and recycling performance. The recycling efficiency is greatly improved.
  
Right Fraction Timing
The time difference due to delay volume from sample detection to fraction is automatically calculated.
 

 
Compact body with minimized dead volume
Minimized internal dead volume and the newly developed non-diffusion recycling system prevent base line shifting and peak broadening.
 

    
 
Simple and Intuitive Operation interface
8.4 inch size touch panel screen allows anyone to operate LaboACE easily on the screen from solvent delivery to fraction collection. 
 

Automate Your Operation
LaboACE LC-7080 offers operators simple and intuitive event programming. Events such as repeating sample injection, discarding junk peaks, recycling and sample collecting can be setup easily. A new feature, Peak Detection, automatically collects samples when peaks start to show.
 
 - Repeat sample injection
 - Stacked injection for solvent and time saving
 - Improving peak resolution by recycling separation
 - Discarding unwanted peaks
 - Fraction collection triggered by peaks
 
Multiple ways of injection
Manual injectior and Repeat injector are standard-equipped. Repeat injector is a direct auto sample loading system for large volume injection or additional same sample injection "repeatedly". Optional loop injector for higher reproducibility is also available.
 
Peak Detection
Automatically collects samples when peaks start to show, triggered by time, peak slope and/or peak height. You will not miss collecting your target peaks.
 
Recycling preparative chromatograph (patented)
The system is equipped with non-diffusion recycling system (patented) that prevents the sample from running back into solvent line, baseline shifting, broadening and damaging detectors with back pressure. It protects detectors, columns and your precious samples.
 
Auto Cleanup Function
It cleans inside the flow channels automatically. Auto cleanup function along with the patented non-diffusion recycling system prevent system residual contamination so that you can obtain ultra pure compounds with confidence. Solvent replacement can also be made much easily.
 
Reliable Solvent Delivery
With more than 50 years' experience of developing recycling technology, the system has JAI-made serial double plunger pump optimized for stable delivery and recycling performance. The recycling efficiency is greatly improved.
  
Right Fraction Timing
The time difference due to delay volume from sample detection to fraction is automatically calculated.
 

Compact body with minimized dead volume
Minimized internal dead volume and the newly developed non-diffusion recycling system prevent base line shifting and peak broadening.
Simple and Intuitive Operation interface
8.4 inch size touch panel screen allows anyone to operate LaboACE easily on the screen from solvent delivery to fraction collection. 
     
     
 

Detectors

Detectors

Two detectors can be fitted in the LaboACE series small body and can detect simultaneously.
 

UV Detector

Especially designed for recycling preparative HPLC with stability and high detection sensitivity. 
 

  UV-254 LA UV-VIS 4ch 400LA UV-VIS 4ch 800LA 
 Wave length Fixed at 254 nm
Select wavelength as option 
4ch variable
from 200 - 400 nm
4ch variable
from 200 - 800 nm 
 Measurement method Single beam     
 Flow cell Optical path length: 0.3 mm Volume: 45 μL
(Option : 1.4 mm and 2.4 mm)

 

RI Detector

It gives quick baseline stabilization and won't require much time before injection.
Applicable for both preparative and analytical HPLC.
 

   RI-700 LA
 Measurement method Deflection
 Flow cell Volume 8 μL
 RI range 1.00 - 1.75

 

Two detectors can be fitted in the LaboACE series small body and can detect simultaneously.
 
UV Detector
Especially designed for recycling preparative HPLC with stability and high detection sensitivity. 
 

  UV-254 LA UV-VIS 4ch 400LA UV-VIS 4ch 800LA 
 Wave length Fixed at 254 nm 4ch variable
 from 200-400 nm
4ch variable
from 200-800 nm
 Measurement Single beam     
 Flow cell 0.3 mm (option : 1.4 mm, 2.4 mm)
45 μL volume

RI Detector
It gives quick baseline stabilization and won't require much time before injection.
Applicable for both preparative and analytical HPLC.
 

   RI-700 LA
 Measurement method Deflection
 Flow cell 8 μL volume
 RI range 1.00 - 1.75

Chromatography Software

Chromatography Software

Chromatogram Data Acquisition Software

JAI Scan acquires up to 5 channels chromatographic information

  JAI Scan
 Number of channel 5
 PC interface USB2.0
 Auto zero Available
 Event signal Injection, Recycle and Fraction
 Start signal Synchronized with injection
 Operating environment JAI Scan software comes with a special PC
 Data transfer CSV, cdf, mat etc.
 Absorption spectrum display Available with UV-VIS 4ch LA

 
 PC Control

You can now monitor and control the touch panel screen of LaboACE LC-7080 through your PC with this new optional software, JAI Control. All the operations from sample injection can be made remotely from safe and comfortable place using your PC.
 

Chromatogram Data Acquisition Software
JAI Scan acquires up to 5 channels chromatographic information
 

  JAI Scan
 Number of channel 5
 PC interface USB2.0
 Auto zero Available
 Event signal Injection, Recycle and Fraction
 Start signal Synchronized with injection
 Operating environment JAI Scan software comes with a special PC
 Data transfer CSV, cdf, mat etc.
 Absorption spectrum display Available with UV-VIS 4ch LA 

 
PC Control
You can now monitor and control the touch panel screen of LaboACE LC-7080 through your PC with this new optional software, JAI Control. All the operations from sample injection can be made remotely from safe and comfortable place using your PC.

Specifications

Specifications

  LaboACE LC-7080
 Pump P-LA80 
 Solvent delivery system Reciprocating serial double plunger
 Flow rate range 0.1- 80.0 mL/min
 Maximum discharge pressure 20 MPa(0.1 - 15.0 mL/min)
15 MPa(15.1 - 60.0 mL/min)
10 MPa(60.1 - 80.0 mL/min)
 Plunger 7.0 mm ID
 Stroke 8 mm 
 Discharge rate per stroke 300 μL
 Gradient module Optional : Low pressure binary gradient.
It supports mixing two solvents isocratically for recycling separation.
 Variable injector (Manual)  Rheodyne 7725i
 Sample loop  10 mL as standard
 Repeat injector Built-in Direct auto sample loading system 0.1 to 99.9 mL,99 injections
 Loop injector Optional : Sample loop 20 mL as standard. Auto injection up to 999 times.
 Recycle system With non-diffusion function recycling system (Patented)
 Recycle method Switching scheme of solenoid valve
 Auto program
  ・Event programming
  ・Auto fraction collection
  ・Auto replay
  ・Stacked injection

 Set and save 3 programs with up to 30 different events each.
 Automate 99 fraction collections triggered by peak slope and/or peak height.
 Auto-replay the whole program with injection of additional samples successively.
 Utilize the time spent waiting for peak elution when injecting successively additional samples.
 Fraction collector Standard : Built-in 9 ports fraction
Optional : External fraction collector with 33 ports.
15 ports or 6 ports are also available.
 Touch panel 8.4 inch LCD touch panel
 Pressure display and limiter Display and program on LCD touch panel
 Event signal  Injection, Recycle and Collect
 Auto cleanup function To wash flow channel by program
 Pump stop timer  To stop pump at 0 - 999 mins
 Bottle capacity To move to a next fraction bottle at 0-999 mL when collecting to prevent from overflow
 Timer with alarm To set alarm at 0 - 999 mins
 Dimensions 382(W) x 555(H) x 432(D) mm
 Weight 40 Kg
 Power  100V, 500VA/200 - 240V, 500VA 
 Column stand Optional
 Solvent tank stand Optional

 

  LaboACE LC-7080
 Pump model P-LA80 
 Solvent delivery system Reciprocating serial double plunger
  Flow rate 0.1 - 80.0 mL/min
 Maximum discharge pressure 20 MPa(0.1 - 15.0 mL/min)
15 MPa(15.1 - 60.0 mL/min)
10 MPa(60.1 - 80.0 mL/min)
 Plunger  7.0 mm ID
 Stroke  8 mm
 Discharge rate per stroke  300 μL
 Gradient module Option : Low pressure binary gradient. It supports mixing two solvents isocratically for recycling separation.
 Variable injector (Manual)  Rheodyne 7725i
 Sample loop  10 mL (standard)
3 mL, 5 mL, 15 mL (optional) 
 Repeat injector Built-in Direct auto sample loading system 0.1 to 99.9 mL,99 injections
 Loop injector Option : Sample loop 20 mL as standard. Auto injection up to 999 times.
 Recycle system With non-diffusion function recycling system (Patented)
 Recycle method Switching scheme of solenoid valve
 Auto program
・Event programming
・Auto fraction collection
・Auto replay
・Stacked injection

 Set and save 3 programs with up to 30 different events each.
 Automate 99 fraction collections triggered by peak slope and/or peak height.
 Auto-replay the whole program with injection of additional samples successively.
 Utilize the time spent waiting for peak elution when injecting successively additional samples.
 Fraction collector Standard : Built-in 9 ports fraction
Optional : External fraction collector with 33 ports. 15 ports or 6 ports can also be selected (optional).
 Touch panel 8.4 inch touch panel screen 
 Pressure display and limiter Program and display on LCD  
 Event signal  Injection, Recycle and Collect
 Auto cleanup function Enables to wash flow channel by program
 Pump stop timer  Enables to stop pump at 0-999 mins
 Bottle capacity Enables to prevent from overflow
in a collection bottle
 Timer with alarm Enables to set alarm at 0-999 mins
 Dimensions 382(W) x 555(H) x 432(D)mm
 Weight 40 Kg
 Power  100V, 500VA/200 - 240V, 500VA 
 Column stand Optional
 Solvent tank stand Optional