LC-9210NEXT / LC-9225NEXT
Manual operation model   
Smart and compact!!
Small, Light, Reasonable

Recycling preparative HPLC
Compact sized standard model
NEXT series Manual operation model


All functions from injection to fraction are designed to fit into a compact body.

Manual use only Specialized in manual operation, it helps to separate different samples every time.

With non-Diffusion function Recycling system (Patent in Japan)NEW!
During extended recycling period, the recycled sample in the flow line may diffuse back into the solvent with the danger of contaminating the solvent reservoir. The NEXT series has non-diffusion device (patent) that prevents the sample from running back into the solvent line and also damaging your columns and detectors with back pressure.

Auto cleanup function NEW!
Keeps the flow channels clean automatically.
Solvent changeover when changing columns
is also made much easier.

Pumps depend on column sizes
LC-9210 NEXT Maximum flow rate: 10.0mL/min
LC-9225 NEXT Maximum flow rate: 25.0mL/min
Please select a model with your column size



Now 1/3* Body size
Old model
*compared to our previous model line


Improved layout
Manual injector is mounted outside of the body. Maintenance such as seal exchange becomes greatly easy. The pump and the detectors are also easily taken out by opening the front panel.

Easy setup on the panel
The sheet switch panel has all necessary operational functions such as start the pump, set up the flow rate and detectors, recycling and collecting as well as auto cleanup.

Auto calculation for right fraction timing
The time difference between detection and actual fraction will be automatically calculated and programmed.
Flow channel



Detectors
Two different types of detectors small enough to fit into NEXT series body have been developed. They can be installed together and perform detection simultaneously.

 
UV detector
As preparative dedicated detector, it has developed its stability and sensitivity can detect most organic compounds.
UV-
254NEXT
UV-
370NEXT
UV-
600NEXXT
Wave length
254mm
195-370mm
195-
600mm
Measurement Method

Double beam filter

Double beam
Flow Cell
Cell Length: 0.5mm, Cell volume: 20µl
(Option: 0.2mm, 0.1mm)
RI Detector
Stable baseline can be obtained quickly. Applicable for both preparative and analytical HPLC.
RI-700NEXT
Measurement Method
Deflection
Flow Cell
8µl volume
RI Range
1.00-1.75
Attenuator
1-2000, in 12 steps