Japan Analytical Industry Co., Ltd.
SITEMAP | SERCH
powered by Google
HOME COMPANY COMPANY APPLICATION SERVICE AGENT LIST CONTACT US
ChineseKoreanJapanese
Recycling Preparative HPLC
LC-9110/9130
NEXTseries
LC-9210/9225
NEXTseries
LC-200/500NEXT
For larger scale
LC-250HS
Full Automated Large Scale Preparative Model
LC-9201/9204
LC-9101
LC-9104
LC-9105
LC-9102/9103
Column
Ultraviolet Detector
Refractive Index Detector
Degasser Unit
Chromatogram data acquisition system
JDS-50/100
(for LC-9210/9225)

Prepure
(for LC-9110/9130)
Solvent Recycler
Curie Point Pyrolyzer
Thermal Desorption
(Curie Point Purge & Trap Sampler)
Outgas Collector for Thermal Desorption
Cryogenic Sample Crusher

LC-200NEXT/500NEXT
Cute outside but Powerful inside !    

Pump, Detector(s) and Injector are all installed in a cute body but hold maximum discharge pressure up to 20Mpa.
High throughput with stable high flow rate NEW!
Avalable two models depends on required column flow. LC-200NEXT has maximum flow rate up to 200mL/min and LC-500NEXT has up to 500mL/min.

Recycle with Non-diffusion function (patent) for solvent saving
Our over-the-years-exclusive focus on "Recycling technique" has been of course applied into both models. During recycle mode, it stops consumption of solvent that leads high cost performance and good for environment..

Reciprocating triple plunger NEW!
Reciprocating Triple Plunger enables stable flow supply without pulsation.

Ease of use with large sized LCD touch pannel
8.4' touch pannel has installed for user friendly operation. Soon after try it, you will see how easy this is!!


·
You can select from 4 different colors.
Auto cleanup
Automated cleanup function keeps the flow channels always clean for accurate fractionation. Solvent change over is also much easier than ever.



PC controll software Prepure-250
With optional PC controlling sofware Prepure-250, it enables not only controlling LC-200/500 remotely but data acquisition and eddition, auto peak mode fraction as well as auto repeat operation will be possible.

Model
Prepure-250
Number of Channel
2
PC Interface
USB2.0
Driver
Exclusive LC-200/500
Event Signal
Marker (Injection, Recycle, Collect, Start)
PC Requirements
WindowsXP or later OS / 32bit
Data Transfer
to MS Excel
Function
Quantitative and Peak area calculation



Detectors
 
UV detector
As preparative dedicated detector, it has developed its stability and sensitivity can detect most organic compounds.
For LC-200NEXT
For LC-500NEXT
Model
UV-
254TNEXT
UV-
370TNEXT
UV-
600TNEXT
UV-
254FNEXT
UV-
370FNEXT
UV-
600FNEXXT
Wave length
Fixed 254nm
195-370nm
195-
600nm
Fixed 254nm
195-370nm
195-
600nm
Zero Adjustment
Auto zero function
Light Source
Deuterium lamp
Sensitivity
0.00005ABU
Drift
0.002ABU/hr (254,370) / 0.0005ABU/hr (600)
Flow Cell
Cell length 0.5mm (Option 0.2mm)
Saturation
Benzen4% with 0.5mm cell

RI Detector
Stable baseline can be obtained quickly. Applicable for both preparative and analytical HPLC.
For LC-200NEXT
For LC-500NEXT
Model
RI-700T NEXT
RI-700F NEXT
Measurement Method
Deflection
Flow Cell
20µl
50µl
RI Range
1.00-1.75
Attenuator
1-2000, in 12 steps
Temp. control
N/A
Zero Adjustment
Auto zero function
Reference Purge
Solenoid valve