HOME | Products | Curie Point Injector | Copy JCI-77

JCI-77

JCI-77

Advanced Portable Pyrolyzer

New model with further consummated quantitativity, reproducibility and usability.

Advanced Portable Pyrolyzer

New model with further consummated quantitativity, reproducibility and usability.

Being Portable
JCI-77 can inject pyrolyzates and generated gas into GC inlet only when needed. It does not require complicated installation to be positioned on the GC injection port. Exactly like the way as micro syringe injection, insert the needle of JCI-77 to the GC septum to make an inject and remove it after injection.
 
Flow channel are replaceable per analysis
Because the JCI-77 probe is not positioned on the GC, it is easy to replace the sample tube and needle every time, that makes the flow channel stay clean for additional analysis and minimize the risk of potential residue remaining in the flow channel. The used sample tube and needle can be cleaned and reused many times.
 
High preheating temperature
Preheating temperature for sample tube (sample chamber) can be raised up to 250°C, 100°C higher than the previous model. Quantitativity and reproducibility have been further improved.
 
Sample Tube Baking Mode
Able to bake sample tube and mini-PAT*. The baking procedure is pre programmed and requires a simple one push of button.
 
Solvent Purge Mode
Able to remove water and solvent trapped in mini-PAT* before analysis of VOC.


 
 
mini-PAT an adsorption tube
mini-PAT is an adsorption tube for VOC analysis. The mini-PAT is composed of an empty sample tube filled with adsorbent (Tenax GR as standard) and a piece of pyrofoil (280°C as standard and a foil is wrapped around the adsorbent). It can potentially be applied, for example, odor analysis at work environment or food products.
 
Air Sampler JAS-50MP
 
 Useful for collecting environmental odor components.
 Automatic collection completes with a few parameter setting. 
 A fitting to connect with mini-PAT comes as a standard accessory.
 
 Flow rate: 0.05 to 5.0 L/min
 

 

 
Being Portable
JCI-77 can inject pyrolyzates and generated gas into GC inlet only when needed. It does not require complicated installation to be positioned on the GC injection port. Exactly like the way as micro syringe injection, insert the needle of JCI-77 to the GC septum to make an inject and remove it after injection.
 
Flow channel are replaceable per analysis
Because the JCI-77 probe is not positioned on the GC, it is easy to replace the sample tube and needle every time, that makes the flow channel stay clean for additional analysis and minimize the risk of potential residue remaining in the flow channel. The used sample tube and needle can be cleaned and reused many times.
 
High preheating temperature
Preheating temperature for sample tube (sample chamber) can be raised up to 250°C, 100°C higher than the previous model. Quantitativity and reproducibility have been further improved.
 
Sample Tube Baking Mode
Able to bake sample tube and mini-PAT(TenaxGR). The baking procedure is pre programmed and requires a simple one push of button.
 
Solvent Purge Mode
Able to remove water and solvent trapped in mini-PAT before analysis of VOC.
 
*mini-PAT is an adsorption cartridge for VOC analysis. The mini-PAT is composed of an empty sample tube filled with adsorbent (Tenax GR as standard) and a piece of pyrofoil (280°C as standard and a foil is wrapped around the adsorbent). It can potentially be applied, for example, odor analysis at work environment or food products.
 
 
 
LinkIcon Pyrofoil How to prepare your sample for pyrolyzer
LinkIcon Portable Pyrolyzer JCI-55 How to Use
 

Specifications

Specifications

 Probe  
 Heating system Curie Point Heating
 Pyrolysis  Pyrofoils from 160°C to 1040°C
 Oven heater 250°C
 Transfer line
 (Needle upper part)
300°C (at the time of Curie point heating)
 Sample tube  Quartz glass, OD 5.5 mm, Length 36 mm 
 Needle  Needle (OD 0.47 mm, Length 42 mm)
 Connection cable 1.5 m  
 Dimensions 38 mm OD x Length 160 mm
 Weight 110 g  
 Power Supplied from controller

 Controller  
 RF power 48W, 600kHz
 Pyrolysis time 5 sec, 10 sec, 15 sec, 30 sec
 Output signal GC start signal
 Mode selection Analysis mode
Solvent purge mode
Baking mode
 Carrier gas He or N2 (0.5 MPa or more)
 Dimensions W140 x D347 x H246 mm
 Weight 7 Kg
 Power AC85 to 240V, 500VA (Max)

 Standard accessories  
 Sample tube 4ea  Needle 5ea
 mini-PAT (TenaxGR) 1ea  Sample tube guide 2ea
 Foil climper 1ea  Sample tube stand 1ea
 Titanium tweezers 1ea  Syringe for needle cleaning 1ea
 Flat nose pliers 1ea  GC start cable 1ea
 Pyrofoil * 1ea  Pyrofoil mix 1pk
* Temperature can be selected.


Optional accessories
 mini-PAT (TenaxGR)
 Air sampler JAS-50MP, with mini-PAT fitting

 
 

 Probe  
Heating system Curie point heating
Pyrolysis  Pyrofoils from 160°C to 1040°C
Oven heater 250°C
Transfer line
(Needle upper part)
300°C
(at the time of curie point heating)   
sample tube   Quartz glass
(5.5 mm OD, Length 36 mm)
Needle Exclusive needle
(0.47 mm OD, Length 42 mm)
Connection cable 1.5 m  
Dimensions 38 mm OD x Length 160 mm  
Weight 110 g  
Power Supplied from controller

 Contolloller  
RF power 48W, 600kHz
Pyrolysis time  5 sec, 10 sec, 15 sec, 30 sec
Output signal  GC/start signal
Mode selection Analysis mode,
Solvent purge mode
Baking mode
Carrier gas He or N2 (0.5 MPa or more)
Dimensions W140 x D347 x H246 mm
Weight     7 Kg
Power AC85 to 240V, 500VA (Max)

Standard accessories
Sample tube 4 ea
mini-PAT (TenaxGR) 1 ea
Needle 5 ea
Sample tube guide 2 ea
Sample tube stand 1 ea
Foil climper 1 ea
Flat nose pliers 1 ea
Titanium tweezers 1 ea
GC start cable 1 ea
Pyrofoil 1 ea 
Pyrofoil mix 1 p/k
Syringe for needle cleaning 1 ea

Optional accessories
mini-PAT (Tenax GR)
Air sampler JAS-50MP
with mini-PAT fitting